Installation Specifications
Top View - Downdraft ERV3015 with Slide-In, Self-Rimming Installation, 
3” Side Panels Installed - Cabinet Depths 23 3/8” to 26 3/8”
Top View - Downdraft ERV3015 with Slide-In, Self-Rimming Installation, 
3” Side Panels Removed -  Min. Required Cabinet Depth: 26 3/8”
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
downdraft vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets 
3/8” min. (1.0 cm)
 countertop overhang
1” min. (2.6 cm)
to any combustibles 
above counter both sides
20 3/8”
 (51.8 cm)
to
23 3/8”
 (59.4 cm)
20 3/8”
 (51.8 cm)
2 5/8” (6.7 cm)
Countertop front
Max. 
overhang 
1 5/8”
 (4.1 cm)
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
downdraft vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)
2
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets 
3/8” min. (1.0 cm)
 countertop overhang
1” min. (2.6 cm)
to any combustibles 
above counter both sides
23 3/8”
 (59.4 cm)
2 5/8” (6.7 cm)
Countertop front
Max. 
overhang 
1 5/8”
 (4.1 cm)
Cabinet Cutouts for Self-Rimming Installation with Downdraft Vent (Models RNR30NIS and RNR30NIFS Only)
2
 To create a “built-in look” on the front of the 
cabinet, this dimension may be changed to 29 1/4” 
(74.3 cm), with the width at the notches remaining 
30 1/16”. This configuration is only for models 
RNR30NIS and RNR30NIFS with the side panels 
behind the door removed.
• 
Trim kit PN ATKR30SR is required for proper 
installation of a downdraft vent with this range.
• 
The self-rimming installation of the RNR30NI[F]S 
range and ERV3015 downdraft vent create a “built-
in” look where the range trim overlaps and rests 
on the countertop on both sides and the downdraft 
vent trim overlaps the countertop in back. The 
ATKR30SR trim kit, installed on the back of the 
range, will cover the front of the downdraft vent 
chassis.
• 
Observe all vertical cabinet clearances on  
page 5.
• 
A self-rimming countertop configuration is required 
for downdraft vent installation. On installations 
with a downdraft vent, when sliding the range into 
position, it will stop when the rear of the control 
panel or side panels contact the notches toward 
the front of the countertop.
34 3/4”
 (88.3 cm)
to
36 7/8”
 (93.7 cm)
(see diagrams)
Countertop
1 5/8 (41.1 cm)
max. thickness
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.