Summit ACR1717LH 정보 가이드

다운로드
페이지 7
_________________________________________________________________________________________________ 
Date: November 12, 2012 
 
KLEA®134a 
Revision 4 
 
Page 3 of 7 
HFC-134a is not flammable in air under ambient conditions of temperature and pressure.  
Under conditions of high temperature and pressure, certain HFC-134a/air mixtures were 
shown to be flammable.  Certain mixtures of HFC-134a and chlorine may be flammable 
under some conditions. 
 
Extinguishing Media:  As appropriate for surrounding materials/equipment.   
 
Fire Fighting Procedures:  Water spray should be used to cool containers.   
 
Fire Fighting Protective Equipment:  Use self-contained breathing apparatus with a full-
face piece and special protective clothing.  
 
6. 
ACCIDENTAL RELEASE MEASURES 
 
Contents under pressure. Ruptured cylinder may rocket or fragment. This product is a liquefied 
gas, which exits the container at temperatures capable of causing freeze burns (frostbite). 
 
Precautions should take into account the severity of the leak or spill. 
 
Move unprotected personnel upwind of leaking container.  Remove ignition sources and ventilate 
the spill area.  Use recommended personal protection and shut off the leak, if without risk.  If 
possible, elevate leak position to highest point of container (should leak gas, not liquid).  Water 
should never be put on leak nor should cylinder be immersed.  If possible, dike and contain 
spillage.  Prevent liquid from entering sewers, sumps, or pit areas since vapor is heavier than air 
and can create a suffocating atmosphere.  Capture material for recycle or destruction if suitable 
equipment is available. 
 
Notify applicable government authority if release is reportable or could adversely affect the 
environment.  
 
7. 
HANDLING AND STORAGE 
 
Handling:  Wear appropriate personal protective equipment. A safety shower and eyewash 
station should be nearby and ready for use. 
 
This product is a liquefied gas, which exits the container at temperatures capable of causing 
freeze burns (frostbite). Ensure personnel are trained in handling and storing cylinders. 
Secure containers at all times. Keep containers closed when not in use. 
 
Ensure there is adequate ventilation or use proper respiratory protection in poorly ventilated 
or confined areas.  Avoid causing and inhaling high concentrations of vapor.  Atmospheric 
levels should be controlled to below the occupational exposure limit and kept as low as 
practicable. 
 
Prevent liquid or vapor from entering sumps or sewers since vapor is heavier than air and 
may form suffocating atmospheres. 
 
Do not put mixtures of HFC-134a with air or oxygen under pressure; do not use such 
mixtures for leak or pressure testing. 
 
Do not heat containers. 
 
Liquid transfers between containers may generate static electricity.  Ensure adequate 
grounding.