Table 3-1 lists the factory-default settings and options for the onboard 
jumpers and switches.
Table 3-1.  VXIpc 800 Series Hardware Default Settings
Jumper/
Switch
Default
Setting
Optional
Setting
W1
Supply SCSI termination 
power
Disable SCSI termination
W2
Normal CMOS operation
Clear CMOS
W4
LPT1 uses DMA Channel 1
LPT uses DMA Channel 3
W13
Enable automatic Slot 0 
detection
Force Slot 0;
Force Non-Slot 0
S1
Enable Ethernet EEPROM 
configuration
Disable Ethernet EEPROM 
configuration (uses default 
power on values)
S2
Enable MITE 
self-configuration
Disable MITE 
self-configuration
S3
Source CLK10 from 
onboard oscillator
Source CLK10 from SMB
S4
Non-inverted CLK10 
output
Inverted CLK10 output
S5
Receive CLK10 input from 
SMB
Source CLK10 output to 
SMB
S6
No termination on CLK10 
input
Terminate CLK10 input 
to 50 
Ω
S7
No termination on external 
trigger input
Terminate external trigger 
input to 50 
Ω
S8
GPIB uses IRQ11
GPIB uses IRQ5
S9
MITE user configuration
MITE factory configuration