Chapter 3
VXIpc 800 Series Configuration and Installation
© National Instruments Corporation
3-5
Figure 3-2.  VXIbus Slot Configuration
When the VXIpc-800 is installed in Slot 0, it becomes the VXIbus 
System Controller. In this role, it has VXIbus Data Transfer Bus Arbiter 
circuitry that accepts bus requests on all four VXIbus request levels, 
prioritizes the requests, and grants the bus to the highest priority 
requester. As VXIbus System Controller, the VXIpc-800 also drives the 
16 MHz VXIbus system clock by an onboard 16 MHz oscillator.
As required by the VXIbus specification, the VXIpc-800 drives the 
10 MHz signal CLK10 on a differential ECL output when installed in 
Slot 0. When not installed in Slot 0, the VXIpc-800 only receives the 
CLK10 signal.
VXIbus CLK10 Routing
When the VXIpc-800 is installed in Slot 0 of your mainframe, it 
supplies the VXIbus CLK10 signal. The VXIpc-800 can use two 
different sources to generate this signal: an onboard oscillator, or the 
external CLK SMB connector. Use switch S3 to select these options, as 
shown in Figure 3-3.
W13
a. Manual Non-Slot 0
Configuration
b. Automatic Slot 0
Detection (Default)
c. Manual Slot 0
Configuration
W13