StorageTek 9714 사용자 설명서
95698
Eighth Edition
3-7
Operating in Manual Mode
Replacing the Expired Cleaning Cartridge
To replace the expired cleaning cartridge:
1. Press
MENU
until the operator panel displays “PRESS EXECUTE TO
REPLACE CLN CART.”
2. Press
EXECUTE
.
The operator panel displays “PRESS EXECUTE TO REPLACE DLT CART.”
3. Press
EXECUTE
.
a. The hand takes the old cleaning cartridge from its cell inside the LSM
and places it into the CAP.
b. The CAP drawer begins to slide toward you.
4. Pull the drawer further toward you. Hold onto the drawer.
5. Remove the expired cartridge from the CAP.
6. Throw away the old cartridge.
7. Place one new cleaning cartridge into the CAP cell.
8. Slide the CAP drawer into the LSM. The lock automatically engages.
a. The robot performs a brief audit.
b. The operator panel displays “MOVING CLEANING CART TO CELL.”
c. The hand places the cartridge into its cell.
d. The operator panel displays “ONLINE CAP UNLK DISABLD” or
“ONLINE - PRESS EXE TO UNLK CAP.”
■
Operating in Manual Mode
The following pages contain operations you can perform when the LSM is in
manual mode. Manual mode occurs when the LSM is no longer online or loses
power.
manual mode. Manual mode occurs when the LSM is no longer online or loses
power.