Hoshizaki MRH/3 사용자 설명서

다운로드
페이지 94
47
2. Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reaches 48°F (9°C) at the 
evaporator outlet and the control board reads 3.9 kΩ from the thermistor. The harvest 
timer is factory set, and generally no adjustment is required. However, a setting longer 
than the factory setting may be advised in cases where the drain provided at harvest 
needs to be prolonged for extra cleaning. Before changing this setting, contact Hoshizaki 
Technical Support at 1-800-233-1940 for recommendations. Keep in mind that setting the 
harvest timer to a longer setting decreases 24-hour production.
Note that the pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer 
during cycles with a pump out. For details, see "III.C.3. Pump-Out Timer (S4 dip switch 
3 & 4)."
 
Note: On models with a pump-out every cycle, the harvest timer is only relevant during 
the initial harvest cycle since a pump out occurs every cycle thereafter. 
S4 Dip Switch Setting
Time 
(sec.)
No. 1
No. 2
OFF
OFF
60
ON
OFF
90
OFF
ON
120
ON
ON
180
3. Pump-Out Timer (S4 dip switch 3 & 4)
NOTICE
• On KM-515M_H models without harvest pump timer operation, never 
adjust the pump-out timer's harvest timer (T2) for a time less than 
150 sec. Otherwise, the icemaker will not perform properly. 
• On models with harvest pump timer, do not adjust 3 off and 4 on. Pump 
does not run in pump-out rotation in this setting.
When a pump-out is called for, the pump motor stops for 2 sec., then energizes in the 
reverse direction, taking water from the bottom of the water tank and forcing pressure 
against the check valve seat allowing water to go through the check valve and down 
the drain. At the same time, water flows through the small tube to power flush the float 
switch. The pump motor drains the water tank for the time determined by the pump-out 
timer. The pump-out timer also acts in place of the harvest timer during cycles with a 
pump-out. The pump-out timer is factory set, and generally no adjustment is required. 
However, where water quality is bad and the icemaker needs a longer pump-out time, 
the pump-out timer can be adjusted. The pump-out timer control can be set to pump-out 
for 10 or 20 sec.
S4 Dip Switch Setting
Time (sec.)
Inlet Water 
Valve
No. 3
No. 4
T1
T2
OFF
OFF
10
150
Closed
ON
OFF
10
180
Closed
OFF
ON
10
120
Open
ON
ON
20
180
Closed
T1: Time to drain the water tank
T2: Harvest timer at pump out