6 – Port Configuration
Configuring Port Threshold Alarms
6-10
59183-01 A
S
6.5
Configuring Port Threshold Alarms
The switch can monitor a set of port errors and generates alarms based on 
user-defined sample windows and thresholds. These port errors include the 
following:
„
Cyclic Redundancy Check (CRC) errors
„
Decode errors
„
ISL connection count
„
Device login errors
„
Device logout errors
„
Loss-of-signal errors
You make changes to the port threshold alarms by modifying the switch 
configuration as described in 
. Refer 
 for a description of the port alarm threshold parameters.
The switch will down a port if an alarm condition is not cleared within three 
consecutive sampling windows (by default 30 seconds). Reset the port to bring it 
back online. An alarm is cleared when the threshold monitoring detects that the 
error rate has fallen below the falling trigger.