Hitachi SJ300 Series 사용자 설명서

다운로드
페이지 294
SJ300 Inverter
Motor C
ontrol
Acc
e
ssor
ies
5–11
The table below lists the performance of 400V-class inverter models with the optional external 
braking units. In some cases, the resistor selection specifies multiple resistors in a parallel, 
series, or combination parallel/series configuration. The example diagram shows a combination 
parallel / series configuration. Please refer to the braking unit manual for detailed wiring 
diagrams.   
–550LFU
BRD–E2–30K
HRB3 x (2)
parallel
8.5
2400
20
30
HRB3 x (3)
parallel
5.7
3600
20
40
HRB3 x (4)
parallel
4.3
4800
20
60
200V Class
Braking Unit
Dynamic Braking Resistor Selection
Max. 
Braking 
Torque, 
%
Model Number
SJ300
Type
Type
x (quantity)
Series or 
Parallel
Total 
Ohms
Total 
Watts
Max. 
Duty 
Cycle, 
%
Braking 
Unit
HRB3 x (6)...
(3)  parallel x 2 series
Inverter
Example configuration
400V Class
Braking Unit
Dynamic Braking Resistor Selection
Max. 
Braking 
Torque, 
%
Model Number
SJ300
Type
Type
x (quantity)
Series / 
Parallel
Total 
Ohms
Total 
Watts
Max. 
Duty 
Cycle, 
%
–150HFU/HFE
BRD–EZ2
HRB1 x (2)
series
100
800
10
40
HRB2 x (2)
series
70
1200
10
60
HRB3 x (2)
series
34
2400
10
110
BRD–EZ2–30K
HRB3 x (4)
(2) parallel
 x 2 series
17
4800
10
190
HRB3 x (6)
(3) parallel
 x 2 series
11.3
7200
10
200
–185HFU/HFE
BRD–EZ2
HRB1 x (2)
series
100
800
10
40
HRB2 x (2)
series
70
1200
10
50
HRB3 x (2)
series
34
2400
10
90
BRD–EZ2–30K
HRB3 x (4)
(2) parallel
 x 2 series
17
4800
10
170
HRB3 x (6)
(3) parallel
 x 2 series
11.3
7200
10
200
–220HFU/HFE
BRD–EZ2
HRB1 x (2)
series
100
800
10
35
HRB2 x (2)
series
70
1200
10
45
HRB3 x (2)
series
34
2400
10
80
BRD–EZ2–30K
HRB3 x (4)
(2) parallel
 x 2 series
17
4800
10
150
HRB3 x (6)
(3) parallel
 x 2 series
11.3
7200
10
200