Texas Instruments 28xxx 사용자 설명서

다운로드
페이지 119
www.ti.com
Time-Base Submodule Registers
Table 4-4. Time-Base Control Register (TBCTL) Field Descriptions (continued)
Bit
Field
Value
Description
6
SWFSYNC
Software Forced Synchronization Pulse
0
Writing a 0 has no effect and reads always return a 0.
1
Writing a 1 forces a one-time synchronization pulse to be generated.
This event is ORed with the EPWMxSYNCI input of the ePWM module.
SWFSYNC is valid (operates) only when EPWMxSYNCI is selected by SYNCOSEL = 00.
5:4
SYNCOSEL
Synchronization Output Select. These bits select the source of the EPWMxSYNCO signal.
00
EPWMxSYNC:
01
CTR = zero: Time-base counter equal to zero (TBCTR = 0x0000)
10
CTR = CMPB : Time-base counter equal to counter-compare B (TBCTR = CMPB)
11
Disable EPWMxSYNCO signal
3
PRDLD
Active Period Register Load From Shadow Register Select
0
The period register (TBPRD) is loaded from its shadow register when the time-base counter,
TBCTR, is equal to zero.
A write or read to the TBPRD register accesses the shadow register.
1
Load the TBPRD register immediately without using a shadow register.
A write or read to the TBPRD register directly accesses the active register.
2
PHSEN
Counter Register Load From Phase Register Enable
0
Do not load the time-base counter (TBCTR) from the time-base phase register (TBPHS)
1
Load the time-base counter with the phase register when an EPWMxSYNCI input signal occurs or
when a software synchronization is forced by the SWFSYNC bit.
1:0
CTRMODE
Counter Mode
The time-base counter mode is normally configured once and not changed during normal operation.
If you change the mode of the counter, the change will take effect at the next TBCLK edge and the
current counter value shall increment or decrement from the value before the mode change.
These bits set the time-base counter mode of operation as follows:
00
Up-count mode
01
Down-count mode
10
Up-down-count mode
11
Stop-freeze counter operation (default on reset)
Registers
96