FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:  If you do not follow these instructions exactly, a fire or explosion may result caus-
ing property damage, personal injury or loss of life.
A.   This appliance has a pilot which must be lighted by hand.  
When lighting the pilot, follow these instructions exactly.
B.   BEFORE LIGHTING  smell all around the appliance area 
for gas.  Be sure to smell next to the floor because some 
gas is heavier than air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; 
  do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's 
phone.  Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire 
department.
C.   Use only your hand to push in or turn the gas control 
knob.  Never use tools.  If the knob will not push in 
or turn by hand, don't try to repair it; call  a  qualified 
service technician.  Force or attempted repair may result 
in a fire or explosion.
D.   Do not use this appliance if any part has been under 
water.  Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the 
control system and any gas control which has been under 
water.
TO TURN OFF GAS TO APPLIANCE
1.   Set the thermostat to lowest setting.
2.   Turn off all electric power to appliance if service is to be 
performed (if applicable).
3.   Remove casing front assembly.
4.   Push in gas control knob slightly and turn clockwise  
 to "OFF." Do not force.
5.   Replace casing front assembly.
1.   STOP!   Read the safety information above.
2.  Set the thermostat to lowest setting.
3.  Turn  off  all  electric  power  to  the  appliance    (if  appli-
cable).
4.   Remove casing front assembly.
5.   Push in gas control knob slightly and turn clockwise    
 to "OFF".
 
 
NOTE:  Knob cannot be turned from "PILOT" to "OFF" 
unless knob is pushed in slightly.  Do not force.
6.   Wait ten (10) minutes to clear out any gas.  Then smell 
for gas, including near the floor.  If you smell gas, STOP! 
Follow "B" in the safety information above.  If you don't 
smell gas, go to the next step.
7.   Remove the pilot access cover located on the combustion 
chamber.  
8.   Find pilot - follow metal tube 
 
from gas control.  The pilot is 
 
behind the pilot access cover.
9.   Turn knob on gas control counterclockwise  
 
to "PILOT."
10.  Push in control knob all the way and hold in.  Imme-
diately light the pilot with the Piezo Pilot Ignitor or a 
match.  Continue to hold the control knob in for about 
one (1) minute after the pilot is lit.  Release knob,  and 
it will pop back up.  Pilot should remain lit.  If it goes 
out, repeat steps 5 through 10.
  • If knob does not pop up when released, stop 
and immediately call your service technician 
or gas supplier.  
  • If the pilot will not stay lit after several tries, 
turn the gas control knob to "OFF" and call 
your service technician or gas supplier.  
11.  Replace pilot access cover.
12.  Turn  gas  control  knob  counterclockwise 
  to 
"ON."
13. Replace casing front assembly.
14.  Turn  on  all  electric  power  to  the  appliance  (if  appli-
cable).
15.  Set thermostat to desired setting.
16.  CAUTION:  Pilot access cover must be kept tightly closed 
during operation.
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS