Empire Comfort Systems DV-25-2SG 사용자 설명서

다운로드
페이지 20
12434-8-0806
Page 12
The correct flame will be almost horizontal, blue and will extend 
past  the  thermopile  1/4"  (6mm).    The  flame  will  surround  the 
thermopile just below the tip.
On propane (LP-gas) slight yellow might occur where the pilot 
flame and burner flame meet.
Natural  gas  pilots  require  adjusting  when  the  inlet  pressure  is 
above  5"  w.c.  (1.25kPa)    Turn  adjustment  screw  clockwise  to 
reduce flame.
Propane (LP-gas) will not require adjusting.
Figure 7
There will be a short blue inner flame with a much larger lighter 
blue secondary flame. The burner flame may have a yellow tip when 
hot. See the burner drawing showing the approximate heights of 
each part of the flame. Dust in the combustion air will produce an 
orange or red flame. Do not mistake the orange or red flame for 
an improper yellow flame. After use, cleaning may be required for 
the proper flame.
Figure 8
Primary Air Adjustment (Figure 9) 
An air adjustment bolt is located on the chamber support bottom.  
The four inch (102mm) clearance between the furnace and the floor 
allows access to the air adjustment bolt. The air adjustment bolt is 
above the rectangular opening on the inner casing bottom.
On Propane gas, if a whistling noise (resonation) occurs, screw 
air adjustment bolt into the chamber support in order to reduce the 
amount of primary air. If the whistling noise (resonation) is not 
eliminated when the air adjustment bolt is screwed into the chamber 
support this may indicate the air adjustment bolt is misaligned. Grasp 
air adjustment bolt and pivot (push) air adjustment bolt away from 
yourself. Observe the main burner flame as you push air adjustment 
bolt and when the main burner flame begins to develop a yellow 
flame, you should stop pushing on the air adjustment bolt. Screw 
air adjustment bolt out of the chamber support until the yellow 
flame on the main burner is eliminated. The air adjustment bolt 
should  now  be  properly  aligned.   The  reduction  in  primary  air 
will soften the main burner flame and will eliminate the whistling 
noise (resonation).
On Propane or Natural gas, if a yellow flame occurs, screw air 
adjustment bolt out of the chamber support but do not completely 
remove air adjustment bolt from chamber support. The repositioning 
of the air adjustment bolt will increase the amount of primary air. 
The increase in primary air will sharpen the main burner flame and 
will eliminate the yellow flame.
Figure 9
PILOT FLAME CHARACTERISTICS
MAIN BURNER FLAME CHARACTERISTICS