Siemens Gigaset S450IP 사용자 설명서

다운로드
페이지 44
29
Appendix
Gigaset S450 IP KBA / EN US / A31008-M1713-R321-2-6043 / appendix.fm / 17.1.07
Ve
rs
ion 4,
 16
.09.
2005
General specifications
FCC / ACTA Information
Warning
: Changes or modifications to this unit 
not expressly approved by Siemens Cordless 
Products could void the FCC authority to oper-
ate the equipment. This includes the addition of 
any external antenna device.
This equipment complies with Part 68 of the 
FCC rules and the requirements adopted by the 
ACTA. On the bottom of the base station is a 
label that contains, among other information, 
a product identifier in the format 
US:AAAEQ##TXXXX. If requested, this number 
must be provided to the telephone company.
A plug and jack used to connect this equipment 
to the premises wiring and telephone network 
nust comply with the applicable FCC Part 68 
rules and requirements adopted by the ACTA. 
A compliant telephone cord and modular plug 
is provided with this product. It is designed to 
be connected to a compatible modular jack that 
is also compliant. See installation instructions 
for details.
The REN is used to determine the number of 
devices that may be connected to a telephone 
line. Excessive RENs on a telephone line may 
result in the devices not ringing in response to 
an incoming call. In most but not all areas, the 
sum of RENs should not exceed five (5.0). To be 
certain of the number of devices that may be 
connected to a line, as determined by the total 
RENs, contact the local telephone company. 
For products approved after July 23, 2001, the 
REN for this product is part of the product iden-
tifier that has the format US:AAAEQ##TXXXX. 
The digits represented by ## are the REN with-
out a decimal point (e.g., 03 is a REN of 0.3). 
For earlier products, the REN is separately 
shown on the label.
If this equipment causes harm to the telephone 
network, the telephone company will notify you 
in advance, that temporary discontinuance of 
service may be required. But if advance notice 
isn’t practical, the telephone company will 
notify the customer as soon as possible. Also, 
you will be advised of your right to file a com-
plaint with the FCC if you belive it is necessary.
The telephone company may make changes in 
its facilities, equipment, operations or proce-
dures that could affect the operation of the 
equipment. If this happens the telephone com-
pany will provide advance notice in order for 
you to make necessary modifications to main-
tain uninterrupted service. If you experience 
trouble with this telephone system, disconnect 
it from the network until the problem has been 
Interfaces
Fixed network, Ethernet
No. of channels
60 duplex channels
Radio frequency-
range
1880–1900 MHz
Duplex method
Time multiplex, 
10 ms frame length
Channel grid
1728 kHz
Bit rate
1152 kbit/s
Modulation
GFSK
Language code 
32 kbit/s
Transmission 
power
10 mW, average power per 
channel
Range
up to 328 yards outdoors, 
up to 55 yards indoors
Base station 
power supply
230 V ~/50 Hz
Environmental 
conditions in oper-
ation
+41°F to +113°F; 
20% to 75% humidity
Dialing mode
DTMF (touch tone dialing)/
DP (dial pulsing)
Flashing time
250 ms
Codecs
G711, G726, G729AB with 
VAD/CNG
Quality of Service TOS, DiffServ
Protocols
DECT, GAP, SIP, RTP, DHCP, 
NAT Traversal (STUN), 
HTTP