Avaya S8400 사용자 설명서

다운로드
페이지 88
Troubleshooting configuring the media server hardware
Installing and Configuring the Avaya S8400 Media Server
February 2006
85
 
LED display on SIPI 
is flashing
SIPI LED has not had an IP address assigned to it (static IP 
addressing)
Cannot access SIPI 
for static addressing
Make sure you are plugged into the Services (top) port on the 
SIPI.
Make sure the ARP cache is cleared on the laptop. In an 
MS-DOS command window, type arp -d 192.11.13.6 and 
press Enter.
No “V” on SIPI LED
SIPI is not connected to Ethernet switch or network. 
Connectcrossover cable between the RJ45 SIPI adapter and 
Eth-A on the S8400 adapter, or, connect cable to bottom port on 
faceplate and to the Ethernet switch or the customer’s network.
“V” on SIPI LED is not 
filled in
SIPI does not have an IP address assigned to it.
SIPI has not been administered.
Get alarm when first 
connect to SIPI
SIPI does not have current firmware. Upgrade firmware.
Troubleshooting for media server hardware configuration  (continued)
Problem
Possible solution
2 of 2