Install and cable a G600 cabinet
Install and cable a G600 cabinet
S8100 Installation and Upgrades
65
November 2003
Install and cable a G600 cabinet
!
WARNING:
Be sure there is adequate ventilation in the area. The internal room temperature must not exceed
50
50
o
C (122
o
F).
A G600 cabinet can be either floor- or rack-mounted. Set the Carrier Address ID either before or after
installing each G600.
installing each G600.
!
WARNING:
It is very important to align the cabinet with the correct holes in the frame because the distance
between each varies. To aid your installation of the rack-mounted cabinet, print a copy of the G600
mounting template provided on this CD. Print the template on 11
between each varies. To aid your installation of the rack-mounted cabinet, print a copy of the G600
mounting template provided on this CD. Print the template on 11
″
× 17
″
paper, so you can use it as
an actual template.
Verify the carrier address ID on G600 cabinets
1
Loosen the thumb screws on the fan assembly and pull it straight out as shown in
Figure 3: Fan assembly removal
2
Verify and, if necessary, set the carrier address ID for each cabinet as shown in
on page 66 and
Figure 4, Setting G600 carrier address ID,
on page 66.
Cabinet A is the processor cabinet, and Cabinets B, C, and D are optional port carrier cabinets.
(S8100 supports up to three cabinets, A, B, and C.)
(S8100 supports up to three cabinets, A, B, and C.)