Panasonic MINAS A5 사용자 설명서

다운로드
페이지 478
2-2
2
 
Preparation
1. Conformance to international standards
EC Directives
EC Directives
7KH(&'LUHFWLYHVDSSO\WRDOOVXFKHOHFWURQLFSURGXFWVDVWKRVHKDYLQJVSHFLÀFIXQFWLRQV
and have been exported to EU and directly sold to general consumers. Those products 
DUHUHTXLUHGWRFRQIRUPWRWKH(8XQLÀHGVWDQGDUGVDQGWRIXUQLVKWKH&(PDUNLQJRQWKH
products.
However, our AC servos meet the relevant EC Directives for Low Voltage Equipment so 
that the machine or equipment comprising our AC servos can meet EC Directives.
EMC Directives
MINAS Servo System conforms to relevant standard under EMC Directives setting up 
certain model (condition) with certain locating distance and wiring of the servo motor and 
the driver. And actual working condition often differs from this model condition especially 
in wiring and grounding. Therefore, in order for the machine to conform to the EMC Di-
rectives, especially for noise emission and noise terminal voltage, it is necessary to ex-
amine the machine incorporating our servos.
Conformity to UL Standards
Remarks
Note
Observe the following conditions of (1) and (2) to make the system conform to UL508C 
(E164620).
(1)  Use the driver in an environment of Pollution Degree 2 or 1 prescribed in IEC60664-1. 
(e.g. Install in the control box with IP54 enclosure.)
(2) Make sure to install a circuit breaker or fuse which are UL recognized (Listed   
PDUNHGEHWZHHQWKHSRZHUVXSSO\DQGWKHQRLVHÀOWHU
8VHDFRSSHUFDEOHZLWKWHPSHUDWXUHUDWLQJRIÝ&RUKLJKHU
    For rated current of circuit breaker and fuse, refer to P.2-10 “Driver and List of Appli-
cable Peripheral Equipments”.
(3)  Over-load protection level
 
Over-load protective function will be activated when the effective current exceeds 
115% or more than the rated current based on the time characteristics (see the next 
SDJH&RQÀUPWKDWWKHHIIHFWLYHFXUUHQWRIWKHGULYHUGRHVQRWH[FHHGWKHUDWHGFXU-
rent. Set up the peak permissible current with Pr0.13 (Setup of 1st torque limit) and 
Pr5.22 (Setup 2nd torque limit).
(4)  Motor over-temperature protection is not provided.
0RWRURYHUORDGWHPSHUDWXUHSURWHFWLRQVKDOOEHSURYLGHGDWWKHÀQDOLQVWDOODWLRQXSRQ
required by the NEC (National Electric Code).
Note
For Overload protection time characterstics, refer to P.6-14.