Buy pressing the MORE screen, you can choose for the temperatures to display in degrees F 
or degree C. (Note; Changing the temperature scale, requires adjusting the alarm values.)
                 
 
When these settings have been made, the operator now has a choice of returning to the 
DRYER MENU, BACK (takes you back to the DRYER SETUP 1 of 3) or pressing MORE 
to take you to screen 3 of 3 of the
 DRYER SETUP screen.  
                 
 
NOTE: At this display, before you change any of the settings, you need to test the 
thermocouple readings in Ice water (32°F at sea level, and boiling water 212°F at sea 
level). Then you may change these settings accordingly to make sure the controller is 
displaying the correct temperature. 
Setting Values 
By pressing and holding the numbers in the LOW TEMP ALARM or the HIGH TEMP 
ALARM
 buttons, the following screen will be displayed: 
 
 
Enter the values you would like to set in the screen by pressing the number keys. Press ENT 
(Enter) when you are finished to set the new values or CLR (Clear) to erase the current 
values and reenter new ones. To set the values in the next field, press ENT (Enter) to close 
the screen shown above.  Then select the next number field to enter new values. 
Over-Drying Protection 
 
 
Portable Drying/Conveying Systems 
Chapter 4:  Operation 