Sterling 882.00294.00 Manual Do Utilizador

Página de 63
The PROCESS RETURN AIR TEMPERATURE displays the air temperature as it leaves 
the drying hopper. If this temperature is above 150°F, an aftercooler is required.  
By pressing the DISABLE or ENABLE the operator disable or enable this feature of the 
dryer. 
This feature is used to prevent the over drying of the plastic resin in the drying hopper. 
 At this point the operator has the choice of pressing MAIN MENUDRYER MENU, or 
MORE to access the screen 2 of 2 of the OVERDY PROTECTION for adjusting values. 
                 
 
SET BACK VALUES; 
The SETPOINT is the secondary drying temperature set point. This is the temperature at 
which the drying temperature will be reduced to after a certain delay time and when the 
return air temperature has exceeded its set point..   
The TEMP is the set point for the return air temperature of the drying hopper. When the 
return air temperature exceeds this value, after a certain delay time, the process temperature 
will be reduced to its secondary value (SETPOINT) to eliminate over drying of the plastic 
material.   
The DELAY is the time which will take for the dryer to switch the drying temperature set 
point from primary drying temperature to secondary drying temperature or back to the 
primary drying temperature set point.  
SET UP TEMP; 
The SETUP TEMP is the secondary temperature setting for the return air temperature. When 
the return air temperature of the drying is lower than this set point, after a certain delay time, 
the process temperature set point will switch back to the primary drying temperature set 
point. 
Once the parameters have been set for the drying process, the operator can return to the 
DRYER MENU, MAIN MENU, or BACK to the screen 1 of 2 of the OVERDRY 
PROTECTION.
 
Setting Values 
By pressing and holding the numbers in the SET BACK DELAY button, the following 
screen will be displayed: 
  
 
 
Portable Drying/Conveying Systems 
Chapter 4:  Operation 
27 of 63