3-313
Computer Telephony Integration (CTI) Link 
3
NOTES:
You should choose a module other than the one that has the system 
programming port so that you can still perform maintenance and system 
programming when the board with the CTI link extension is busied-out. 
Be sure to busy-out the board with the CTI link before starting any 
programming activities.
When you add a CTI link, the system performs the following actions: 
The programmed buttons for that extension revert to the factory settings for 
a non-operator MLX telephone.
Forwarding is deactivated to the extension.
The extension is removed from membership in calling groups.
The extension is removed from membership in coverage groups.
The extension is removed from membership in Service Observing groups, 
or as an Observer of a Service Observing group.
The Extension Directory label for the extension is changed to CTILINK.
The factory setting for alarms is active on this link.
Dial access to pools is removed from the station.
NOTES:
Be sure to restore the board after finishing any programming activities.
If the primary and secondary cover buttons are not removed, the 
following message appears on the programming device (SPM or 
MLX-20L): 
CTI
 
Link
 
Extension
 
xxxx
 
added,
 
but
 
it
 
has
 
primary
 
or
 
secondary
 
cover
 
buttons
 
at
 
other
 
extensions.
 
Please
 
remove
 
them.
Exit