Avaya 03-300430 Manual Do Utilizador
Server Alarms
72 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
21
(cont’d)
199
UltraDMA CRC Error
Count
Count of Cyclic Redundancy Check
(CRC) errors during UltraDMA mode
(Samsung, Seagate, IBM (Hitachi),
Fujitsu - select models, Maxtor, Western
Digital - select models)
200
Write Error Rate (Multi
Zone Error Rate
Total number of errors found when writing
a sector. (Samsung, Seagate, IBM
(Hitachi), Fujitsu, Maxtor, Western Digital)
220
Disk Shift
Indicates how much the disk has shifted
(unit of measure unknown). This error is
critical. An increasing value for this
error may indicate a failing disk drive.
(Seagate)
221
G-Sense Error Rate
Rate of errors occurring as a result of
impact loads such as dropping the drive,
wrong installation, etc. (Seagate, Hitachi)
222
Loaded Hours
Loading on magnetic heads actuator
caused by the general operating time.
223
Load/Unload Retry
Count
Loading on magnetic heads actuator
caused by numerous recurrences of
operations like: reading, recording,
positioning, etc.
224
Load Friction
Loading of magnetic heads actuator
caused by friction in mechanical part of
the store.
226
Load-in Time
Total time of loading on the magnetic
heads actuator.
227
Torque Amplification
Count
Count of efforts of the rotating moment of
a drive
228
Power-Off Retract
Count
Count of the number of times the drive
was powered off.
230
GMR Head Amplitude
Amplitude of the heads trembling in
running mode.
22
WRN
Failed to read smart values/thresholds
This indicates that the smart utility was not able to read the smart values/
thresholds from the drive. The smart utility is unable to function due to drive
access problems.
Table 17: HDD Alarm in Media Server (continued)
Event
ID
Alarm
Level
Level
Alarm Text, Cause/Description, Recommendation
4 of 4