Avaya 03-300430 Manual Do Utilizador
Communication Manager Maintenance-Object Repair Procedures
740 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error log entries and test-to-clear values
Table 251: CAB-EXFR Error Log Entries
Notes:
a. Error Type 1 – Manual on. Run test environment location and follow the repair
steps for Test #1532.
For information on specifying a location, see
b. Error Type 2 – Firmware has activated emergency transfer. This error is not expected. Run
test environment location and follow the repair steps for Test #1532.
c. Error Type 257 – Manual off. Run test environment location and follow the repair
steps for Test #1532.
System technician-demanded test:
Descriptions and error codes
Descriptions and error codes
Error
type
type
Aux
data
data
Associated test
Alarm
level
level
On/Off
board
board
Test-to-clear value
1 (
)
—
Emergency transfer
query test (#1532)
MAJ
On
test environment
location
2 (
)
—
Emergency transfer
query test (#1532)
MAJ
On
test environment
location
—
Emergency transfer
query tesst (#1532)
WRN
On
test environment
location
Order of investigation
Short test
sequence
Long test
sequence
D/ND
Emergency transfer query test (#1532)
X
X
Nondestructive