Desa VGL18NRA Manual Do Utilizador

Página de 32
www.desatech.com
112882-01D
20
Figure 20 - Pilot
Ignitor 
Electrode
Pilot Burner
Ignitor 
Electrode
Pilot Burner
Propane/LP Gas
Natural Gas
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
1.  Turn control knob clockwise 
 to the 
OFF position.
2a.  Set selector switch in the OFF position.
2b. 
If  Using  Optional  Hand-Held  remote:
  Set 
selector switch in the OFF position to keep 
from draining battery. 
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot 
lit by doing one of the following: 
1. Turn control knob clockwise 
 to the 
PILOT position.
2. Use remote control manual OFF button.
3. Set selector switch in the OFF position.
 MANUAL LIGHTING 
PROCEDURE
1.  Follow steps 1 through 6 under Lighting 
Instructions, beginning on page 19.
2.  Depress control knob and light pilot with 
match.
3.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control  knob.  Now  follow  step  9  under 
Lighting Instructions, column 1.   
OPERATING HEATER
Continued
5.  Press in and turn control knob counter-
clockwise 
  to  the  PILOT  position. 
Press in control knob for five (5) seconds 
(see Figure 28). 
 
Note:
 You may be running this heater for 
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be 
pressed in for 30 seconds or more. This will 
allow air to bleed from the gas system.
6.  With control knob pressed in, press and 
release electronic ignitor button. This will 
light pilot. Hold in ignitor button until pilot 
lights.
 
Note:
 If pilot does not stay lit, contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure.
7.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob.
• If control knob does not pop out when 
released, contact a qualified service person 
or gas supplier for repairs.
 
Note:
  If  pilot  goes  out,  repeat  steps  3 
through 7 beginning on page 19.
8.  Slightly push in and turn control knob coun-
terclockwise 
 to the ON position.
9.  Set  flame  adjustment  knob  to  any  level 
between HI and LO.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
Control Knob
Electronic 
Ignitor Button
Flame Adjustment Knob
Figure 28 - Control Knob and Ignitor 
Button Location