INSPECTING BURNERS
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 19.
•  see Troubleshooting, page 22.
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes 
in  the  fitting  at  the  entrance  to  the  burner. 
These holes may become blocked with dust, 
lint or pet hair. Periodically inspect these holes 
for any blockage and clean as necessary. 
Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with 
the heater running. All slotted burner flame 
holes should be open with yellow flame pres-
ent. All round burner flame holes should be 
open with a small blue flame present. Some 
burner flame holes may become blocked by 
debris or rust, with no flame present. If so, 
turn off heater and let cool. Remove blockage. 
Blocked burner flame holes will create soot.
Figure 26 - Correct Pilot Flame Pattern
Figure 27 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
CLEANING AND MAINTENANCE
Check pilot flame pattern and burner flame 
patterns often.
PILOT FLAME PATTERN
Figure 26 shows a correct pilot flame pattern. 
Figure 27 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the heater will shut down.
If pilot flame pattern is incorrect, as shown 
in Figure 27.
 WARNING: Turn off heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater  inspected  yearly  by  a 
qualified service person. Heater 
may need more frequent clean-
ing due to excessive lint from 
carpeting, bedding material, pet 
hair, etc.
 WARNING: Failure to keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INJECTOR HOLDER AND 
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper 
amount of air to mix with the gas. This pro-
vides  a  clean  burning  flame.  Keep  these 
holes  clear  of  dust,  dirt,  lint  and  pet  hair. 
Clean these air inlet holes prior to each 
heating season. Blocked air holes will create 
soot. We recommend that you clean the unit 
every three months during operation and 
have heater inspected yearly by a qualified 
service person.
We also recommend that you keep the burner 
tube and pilot assembly clean and free of dust 
and dirt. To clean these parts we recommend 
using compressed air no greater than 30 PSI. 
Your local computer store, hardware store or 
home center may carry compressed air in a 
can. If using compressed air in a can, please 
follow the directions on the can. If you don’t 
follow directions on the can, you could dam-
age the pilot assembly.