Broan QTXE150FLT Manual Do Utilizador

Página de 8
Page 2
MODELS   QTXE080FLT • QTXE110FLT • QTXE150FLT  
TYPICAL INSTALLATIONS
Housing mounted to I-joists.
Housing mounted anywhere 
between trusses using hanger 
bars.
PLAN THE INSTALLATION
The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number
of elbows will be needed.
Use  a  roof  cap  or  wall  cap  that  has  a  built-in  damper  to
reduce backdrafts.
Plan to supply the unit with proper line voltage and appropri-
ate power cable.
Housing mounted anywhere 
between I-joists using hanger bars.
Housing mounted to joists.
Housing mounted anywhere between 
joists using hanger bars.
Housing mounted anywhere 
between trusses using hanger bars.
INSTALL HOUSING & DUCT
1a. Mount 
housing 
to joist or 
I-joist.
Use a pliers to
bend housing
TABS out
to 90
0
. Hold
housing in
place so that
the housing
tabs contact
the bottom
of the joist.
The housing
mounts with
four (4) screws
or nails. Screw
or nail housing
to joist through
lowest holes in
each mounting
flange, then
through
highest holes.
SPACER
(use for mounting to I-Joist)
I-JOIST
NOTE: Mounting to
I-JOIST (shown) requires use of
SPACERS (included) between the highest hole of
each mounting flange and the
I-joist.
OR
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
ROOF
CAP
*
6-IN. ROUND
ELBOW(S)
*
6-IN.
ROUND
DUCT
*
WALL
CAP
*
*
Purchase
 separately
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
TABS