Louisville Tin and Stove W505F Manual Do Utilizador

Página de 25
A.
This appliance has a pilot which must be lighted
by hand.  When lighting the pilot, follow these in-
structions exactly.
B.
BEFORE LIGHTING smell all around the
appliance area for gas.  Be sure to smell next to the
floor because some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor’s
phone.  Follow the gas supplier’s instructions.
LIGHTING INSTRUCTIONS
MODELS:  W255F, W256F / W355F, W356F / W505F, W506F
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:  If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of  life.
If you cannot reach your gas supplier, call the fire
department.
C.
Use only your hand to push in or turn the gas control
knob.  Never use tools.  If the knob will not push in
or turn by hand, don’t try to repair it, call a qualified
service technician.  Force or attempted repair may
result in a fire or explosion.
D.
Do not use this appliance if any part has been under
water.  Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
LIGHTING INSTRUCTIONS
1.
STOP!  Read the information on the safety label.
2.
Set thermostat to it’s lowest setting.
3.
Open cabinet door.
4.
Depress and turn gas control knob clockwise
to “OFF”.
5.
Wait five (5) minutes to clear out any gas.  Then
smell for gas, including near the floor.  If you smell
gas, STOP!  Follow “B” in the information on the
safety label.  If you don’t smell gas, go to the next
step.
6.
Locate the pilot.  (Follow metal pilot tube from gas
control).
7.
Turn gas control knob counterclockwise                  to
“PILOT”.
8.
Push gas control knob and hold in.  Immediately
light the pilot with a match.  Continue to hold the
gas control knob in for about one (1) minute after
the pilot is lit.  Release gas control knob and it will
pop back up.  Pilot should remain lit.  If pilot goes
out, repeat steps 4 through 8.
If knob does not pop up when released, STOP and
immediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to “OFF” and call your service technician
or gas supplier.
9.
Turn gas control knob counterclockwise                        to
“ON”.
10.
Close the cabinet door.
11.
Set thermostat to desired setting.
TO TURN OFF GAS TO APPLIANCE
1.
Set the thermostat to it’s lowest setting.
2.
Open cabinet door.
3.
Push in gas control knob slightly and turn clockwise
         to “OFF”.  Do not force.
4.
Close cabinet door.
Page 11
Pilot is
located
on side
of burner
Gas Control Knob
Manifold
Pressure Tap
Internal Manifold
Pressure Regulator
Pilot Adjustment
Screw Cap
NOTE:  Knob cannot be turned from “PILOT” to “OFF” unless
knob is pushed in slightly.  Do not force.