Sterling SDA 1000-5100 Manual Do Utilizador

Página de 61
Large Dehumidifying Dryers  
Troubleshooting 
51 
7-3   Alarms 
The Alarm Screen will pop up to show what alarm the dryer is having that moment.  Look 
through the window on the door to see the screen. 
                                     
7-4   Alarm Descriptions 
 
Alarm 
Code 
Alarm Description 
Alarm Effect 
BV 
The Main Air Valve did not maintain or find 
position. 
Possible Motor or Limit Switch Failure. 
Immediate 
Shut Down  
CV 
The Closed Loop Cooling Valve did not find 
position. 
Possible Motor or Limit Switch Failure. 
Immediate 
Shut Down 
PS 
The process supply air temperature switch 
opened. 
Possible thermocouple failure. 
Process 
Shut Down 
RS 
The regeneration air temperature switch opened. 
Possible thermocouple failure. 
Regeneration 
Shut Down 
PH 
Process air temperature deviation is above high 
limit value. 
Possible solid state relay failure. 
Process 
Shut Down 
PL 
Process air temperature deviation is below low 
limit value. 
Possible heater failure. 
Alert Only 
RH 
Regeneration air temperature deviation is above 
high limit value. 
Regeneration 
Shut Down 
DP 
The dew point value is above the high limit 
value. 
Possible ambient air contamination or failed 
regeneration cycle. 
Alert Only 
PB 
Process blower is not running. 
Possible overload fault, contactor fault. 
Process 
Shut Down 
RB 
Regeneration blower is not running. 
Possible overload fault, contactor fault. 
Regeneration 
Shut Down 
PF or RF 
Process air filter (PF) or regen air filter (RF) 
requires cleaning. 
Alert Only 
PR 
The process redundant air temperature 
thermocouple is out of range. 
Possible thermocouple or solid state relay 
failure. 
Immediate 
Shut Down.