Sterling SDA 1000-5100 Manual Do Utilizador

Página de 61
Large Dehumidifying Dryers 
Troubleshooting 
52 
 
7-5   Determining Temperature Controller Errors or Sensor Errors 
Using a Thermocouple 
If the controller displays a temperature that is close to room temperature (70ºF/21ºC) when 
you short-circuit controller input terminals, the controller is normal and the sensor is probably 
broken, short-circuited, or incorrectly wired. 
Using a Platinum Resistance Thermometer 
If the controller displays a temperature of about 0.0°C (32ºF) when you insert a 100-ohm 
resistor between terminals A and –B of the controller, and you short-circuit controller 
terminals +B and –B, the controller is normal and the sensor is probably broken, short-
circuited, or incorrectly wired. 
Other service problems or questions can be answered by contacting the Service 
Department.