1-2
Each of these units is designed to be rugged and durable. They are all fully 
sealed to IP65 standards and are suitable for outside mounting, without the 
need for further weatherproof enclosures. 
Figure 1-1. Typical System 
Layout
Infrared Transmitter Unit 
At the heart of this unit is a small heater assembly designed to give a high 
intensity uniform source of infrared energy over a long lifetime, in excess of 
two years continuous operation, with a power consumption of only 26 watts. 
The heater has a stainless steel cylindrical core, plasma coated with 
refractory, and around which is a 'Kanthal' heating element. This is then 
enclosed within refractory fibers and encapsulated in an aluminium cartridge. 
In the infrequent event of failure, the complete heater assembly can be 
replaced on site within ten minutes. 
Transmitter
Isolation Valve
(If Used)
Pressure
Regulator
Power Supply
Signal Processor
33 ft(10 m) Max.
Mains Supply &
Contact Outputs
Analogue Outputs,
Normalizing Inputs &
Serial Data Port
82 ft(25 m) Maximum Total Cable Length
Between Receiver & Power Supply
33 ft(10 m) Standard
Purge Air
Receiver
Site Mounting
Flange
Air Purge