Enviro 50-029 Manual Do Utilizador

Página de 33
26
Secondary Installation
CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED.
Important note: When the unit is turned on for the first time, It should be turned onto high without the 
fan on for the first 4 hours. This will cure the paint, logs, gasket material and the other products used in 
the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and 
can irritate some people. After the unit has gone through the first burn turn the unit off including the 
pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, 
available at your local ENVIRO dealer.
See Routine M
AINTENANCE
 A
ND
 S
ERVICE
 on how to remove door to clean glass.
3.  A  bag  of  ceramic  fiber  embers  and 
rock  wool  embers  is  provided  gently 
remove  the  ember  material  from  the 
plastic  bag.    Spread  a  layer  loosely 
across the burner tray. Do not allow any 
embers  to  rest  against  pilot  assembly. 
(See diagram provided for proper ember 
placement.)
4.  DO NOT pack this ember material as 
this  could  create  an  unsafe  condition, 
leave embers loose 
5.  Upon  the  first  light  up,  watch  for 
ignition  to  ALL  burner  ports.    If  a 
long  delay  is  noted:  First,  wait  for  the 
appliance to cool down.
•  Open the front door of the appliance.
•  Check  to  carefully  reposition  the 
embers  making  sure  that  burner  ports 
are not plugged solid or blocked.
Figure 36.  Log Placement Step 4.
Figure 37.  Ember Placement.
Figure 38.  Ascot Burning.