 H25-1 Direct Vent Freestanding Gas Stove
15
INSTALLATION
Horizontal Venting with Two (2) 90
o
 Elbows
 Option      V 
         H + H1
     A) 
2'  Min.       4' Max.
     B) 
3'  Min.       5' Max.
     C) 
4'  Min.       6' Max.
     D) 
5'  Min.       7' Max.
     E) 
6'  Min.       8' Max. 
Horizontal Venting with Two (2) 90
o
 Elbows
Option        H 
   V 
  H + H1
     A) 
1' Max.   1' Min.    3' Max.
     B) 
2' Max.   2' Min.    5' Max.
     C) 
3' Max.   4' Min.    6' Max.
     D) 
4' Max.   6' Min.    7' Max.
     E) 
5' Max.   8' Min.    8' Max.
With these options, max. 
total pipe length is 30 feet 
with min. of 8 feet total 
vertical and max. 8 feet 
total horizontal.
Please note min. 1 foot
between 90
o
 elbows is
required.
With these options, maxi-
mum total pipe length is 30 
feet with minimum of 6 feet 
total vertical and maximum 
8 feet total horizontal.
Please note minimum 1 
foot between 90
o
 elbows 
is required.
One 90
o
 elbow = Two 45
o
 elbows.
One 90
o
 elbow = Two 45
o
 elbows.
H
H1
V
H1
H
V
Vent restrictor position A (fully open), refer to the 
"Vent Restrictor Position" section.
Vent restrictor position A (fully open), refer to the "Vent 
Restrictor Position" section.
Lengths do not include elbow indicated
Lengths do not include elbow indicated