Hampton Direct H25-NG1 Manual Do Utilizador

Página de 44
16
Hampton
®
 H25-1 Direct Vent Freestanding Gas Stove
H1
H
V
Vertical Venting with Two (2) 90
o
 Elbows
 
Option  V 
    H 
V + V1 
 
     A) 
1' Min.  4' Max.  2' Min. 
 
     B) 
2' Min.  5' Max.  3' Min. 
 
     C) 
3' Min.  6' Max.  4' Min. 
 
     D) 
4' Min.  7' Max.  5' Min. 
 
     E) 
5' Min.  8' Max.  6' Min. 
Vertical Venting with Two (2) 90
o
 Elbows
With these options, max. total 
pipe length is 30 feet with min. 
of 6 feet total vertical and max. 
8 feet total horizontal.
Please note min. 1 foot 
between 90
o
 elbows is re-
quired.
 
Option   H + H1         V
 
     A) 
 2' Max.     2' Min.
 
     B) 
 3' Max.     3' Min.
 
     C) 
 4' Max.     4' Min.
 
     D) 
 5' Max.     5' Min.
 
     E) 
 6' Max.     6' Min.
 
 
With these options, max. total 
pipe length is 30 feet with min. 
of 6 feet total vertical and max. 
6 feet total horizontal.
Please note min. 1 foot 
between 90
o
 elbows is 
required.
One 90
o
 elbow = Two 45
o
 elbows.
One 90
o
 elbow = Two 45
o
 elbows.
V1
V
H
Vent restrictor position A (fully open), refer to the "Vent 
Restrictor Position" section.
Vent restrictor position A (fully open), refer to the "Vent 
Restrictor Position" section.
Lengths do not include elbow indicated
Lengths do not include elbow indicated
INSTALLATION