gAs CONTrOl vAlve 
CONversION
Convert gas control valve by changing out the 
valve regulator portion of gas valve.
1.  Using a TORX T20 or slotted screwdriver, 
remove  and  discard  three  mounting 
screws,  pressure  regulator  tower,  and 
diaphragm/spring components (see Fig-
ure 5).
2.  Insure  rubber  gasket  is  properly  posi-
tioned  on  new  pressure  regulator  as-
sembly.  Install  new  pressure  regulator 
assembly  to  valve  using  new  mounting 
screws supplied with kit. Tighten screws 
securely  (approximately  25  in-lbs.)  See 
Figure 6.
3.  Install the identification label enclosed with 
gas valve regulator to valve body where it 
can easily be seen (see Figure 6).
Figure 5 - Removing Mounting Screws, 
Pressure Regulator Tower, and 
Diaphragm/Spring Components
O
F
F  P
IL
O
T
   
O
Mounting 
Screws
Pressure 
Regulator 
Tower
Diaphragm/
Spring 
Components
Figure 6 - Installing Pressure Regulator 
Assembly
O
FF
  
PI
L
OT
 
  
ON
 
Mounting Screws
Rubber Gasket
Identification 
Label
CONversION lABelINg AND 
PlACeMeNT
1.  Apply the English and French conversion 
labels over the top of existing certification 
labels (see Figure 7). Existing certification 
labels are located on the lighting instruc-
tion plate inside the gas valve compart-
ment area. With permanent ink, print the 
previous model number on the label in the 
space provided (see Figure 8, page 4).
Figure 7 - Applying English and French 
Conversion Labels Over Existing 
Certification Labels on Lighting 
Instruction Plate
English This 
Side
French This 
Side
Lighting 
Instruction 
Plate