INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMbLY
The pilot assembly is factory preset for the proper flame. Altera-
tions may have occurred during shipping and handling. The pilot 
is located on the back right hand side of the burner.
The  flame  must  envelope  1/4"  of  top  of  the  ignitor/sensor  and 
grounding stem. 
If your pilot assembly does not meet these requirements:
•  Turn the adjustment screw marked PILOT clockwise to decrease 
or counterclockwise to increase the flame to proper size (see 
Figure 49, page 22). Do not remove the adjustment screw.
•  see Troubleshooting, page 25
bURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flame patterns 
will be different from unit to unit and will vary depending on instal-
lation type and weather conditions.
If the vent configuration is installed incorrectly, the flames will lift 
or "ghost". This can be dangerous. Inspect the flames after instal-
lation to ensure proper installation and performance.
Figure 52 shows a typical flame pattern.
If burner flame pattern differs from that described:
•  turn fireplace off (see To Turn Off Gas to Appliance, page 22)
•  see Troubleshooting, page 25
Figure 52 - Typical Flame Pattern
Pilot Burner
Ignitor/Sensor
Figure 51 - Correct Pilot Flame Pattern
Sensing Rod
CLEANING AND 
MAINTENANCE
  WARNING:  turn  off  fireplace  and  let  cool  before 
cleaning.
 CAUtION: You must keep control areas, burners, and 
circulating air passageways of fireplace clean. Inspect 
these areas of fireplace before each use. Have fireplace 
inspected yearly by a qualified service person. Fireplace 
may need more frequent cleaning due to excessive lint 
from carpeting, bedding material, pet hair, etc.
GLASS DOOR
 WARNING: Handle glass door panel with care. Do 
not strike, slam, or otherwise abuse glass. Do not op-
erate fireplace with the glass door removed, cracked, 
or broken.
  WARNING:  Do  not  use  abrasive  cleaners  as  this 
may damage glass. Use a nonabrasive household glass 
cleaner to clean glass. Do not clean glass when hot.
Glass must be cleaned periodically. During start-up it is normal for 
condensation to form on the inside of the glass causing lint, dust, 
and other airborne particles to cling to the glass surface. During 
initial start-up a slight film may form on the glass due to paint cur-
ing. The glass should be cleaned several times with a non-ammonia, 
nonabrasive household cleaner and warm water after the first two 
weeks of operation. Thereafter, clean the glass two or three times 
during each heating season, depending on the usage and circum-
stances present. Refer to Removing/Replacing Glass Door on page 
18 of this manual when removing glass door for cleaning.
 WARNING: Only parts supplied by the manufacturer 
should  be  used  when  replacing  broken  or  damaged 
glass  door  panel  (see  Replacement  Parts,  page  27). 
This glass door panel is a complete unit. No substitute 
materials may be used.
 CAUtION: Wear gloves and safety glasses while 
handling or removing broken glass. Do not remove if 
glass is hot. Keep children and pets away from glass.
If glass has been broken, carefully remove glass door (see Remov-
ing/Replacing Glass Door, page 18). Vacuum all glass pieces with 
a shop vac.
 CAUtION: Do not vacuum if pieces are hot.
Use only the tempered glass door replacement intended for this 
fireplace (see Replacement Parts, page 27 for detail on ordering). 
No  substitutions  may  be  made.  See  Removing/Replacing  Glass 
Door, page 18 for instructions for replacing glass door.
 WARNING: Do not operate fireplace with the glass 
door removed, cracked, or broken.