Johnson Controls R-410A Manual Do Utilizador

Página de 100
505430-BTG-A-0309
Johnson Controls Unitary Products
49
115°F
125°F
3000
77
113.3
12.1
58.5
45.8
33.1
-
-
-
105.9
13.2
57.8
45.0
32.1
-
-
-
72
105.2
12.0
77.8
65.1
52.4
39.7
-
-
97.3
13.2
76.1
63.2
50.4
37.6
-
-
67
97.2
11.9
97.2
84.4
71.7
59.0
46.3
-
88.7
13.1
88.7
81.5
68.7
55.8
43.0
-
62
95.9
11.8
95.9
95.9
86.5
73.8
61.1
48.4
90.6
13.1
90.6
90.6
82.5
69.6
56.8
43.9
57
97.1
11.8
97.1
97.1
86.6
73.9
61.2
48.4
89.5
13.0
89.5
89.5
80.5
67.7
54.8
42.0
3500
77
118.7
12.2
71.3
50.8
36.2
-
-
-
111.3
13.4
72.9
49.8
35.2
-
-
-
72
110.2
12.1
86.5
72.0
57.4
42.8
-
-
102.2
13.3
84.4
69.8
55.1
40.5
-
-
67
101.8
12.0
101.8
93.1
78.5
64.0
49.4
-
93.2
13.2
93.2
89.8
75.1
60.4
45.8
-
62
100.4
11.9
100.4
100.4
94.8
80.2
65.6
51.0
95.2
13.2
95.2
95.2
90.2
75.6
60.9
46.2
57
101.8
12.0
101.8
101.8
94.8
80.3
65.7
51.1
94.0
13.2
94.0
94.0
88.1
73.7
58.8
44.1
4000
77
124.1
12.3
84.0
55.8
39.4
-
-
-
116.6
13.5
88.0
54.6
38.2
-
-
-
72
115.3
12.2
95.2
78.8
62.4
45.9
-
-
107.1
13.4
92.8
76.3
59.9
43.4
-
-
67
106.4
12.1
106.4
101.8
85.4
68.9
52.5
-
97.7
13.3
97.7
97.7
81.5
65.1
48.6
-
62
105.0
12.1
105.0
105.0
103.0
86.6
70.1
53.7
99.7
13.3
99.7
99.7
97.9
81.6
65.0
48.5
57
106.4
12.1
106.4
106.4
103.1
86.7
70.2
53.8
98.5
13.3
98.5
98.5
95.6
79.7
62.7
46.2
4500
72
116.3
12.1
102.8
85.0
67.2
49.4
-
-
107.6
13.3
101.0
83.1
65.1
47.1
-
-
67
107.3
12.0
107.3
105.0
92.0
74.2
56.4
-
98.1
13.3
98.1
98.1
88.7
70.7
52.7
-
62
105.9
12.0
105.9
105.9
104.9
87.1
69.3
51.5
100.2
13.2
100.2
100.2
99.3
81.4
63.3
45.4
57
107.3
12.0
107.3
107.3
105.7
87.9
70.1
52.3
98.9
13.2
98.9
98.9
97.5
79.8
61.5
43.6
5000
72
117.2
12.1
110.4
91.2
72.0
52.9
-
-
108.1
13.3
108.1
89.8
70.3
50.8
-
-
67
108.3
12.0
108.3
108.3
98.6
79.5
60.3
-
98.6
13.2
98.6
98.6
95.8
76.3
56.8
-
62
106.8
11.9
106.8
106.8
106.8
87.6
68.5
49.3
100.7
13.2
100.7
100.7
100.7
81.2
61.7
42.2
57
108.2
11.9
108.2
108.2
108.2
89.0
69.9
50.7
99.4
13.1
99.4
99.4
99.4
79.9
60.4
40.9
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower 
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 
÷
 nameplate rated motor 
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
PH-10 / NH-10  (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65