AIR FoR CoMBUsTIoN 
ANd VeNTIlATIoN
 WARNING: This heater shall 
not  be  installed  in  a  confined 
space  or  unusually  tight  con-
struction unless provisions are 
provided for adequate combus-
tion and ventilation air. Read the 
following instructions to insure 
proper  fresh  air  for  this  and 
other  fuel-burning  appliances 
in your home.
Today’s homes are built more energy efficient 
than ever. New materials, increased insulation 
and  new  construction  methods  help  reduce 
heat  loss  in  homes.  Home  owners  weather 
strip and caulk around windows and doors to 
keep the cold air out and the warm air in. Dur-
ing heating months, home owners want their 
homes as airtight as possible.
While it is good to make your home energy 
efficient, your home needs to breathe. Fresh 
air must enter your home. All fuel-burning ap-
pliances need fresh air for proper combustion 
and ventilation.
Exhaust fans, fireplaces, clothes dryers and 
fuel  burning  appliances  draw  air  from  the 
house to operate. You must provide adequate 
fresh air for these appliances. This will insure 
proper venting of vented fuel-burning appli-
ances.
PROvIDING ADEQUATE 
vENTILATION
The following are excerpts from National Fuel 
Gas  Code, ANSI  Z223.1/NFPA  54,  Section 
5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three 
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help 
you classify your space and provide adequate 
ventilation.
Unusually Tight Construction
The air that leaks around doors and windows 
may provide enough fresh air for combustion 
and ventilation. However, in buildings of un-
usually tight construction, you must provide 
additional fresh air.
Unusually  tight  construction  is  defined  as 
construction where:
a.  walls and ceilings exposed to the outside 
atmosphere  have  a  continuous  water 
vapor retarder with a rating of one perm 
(6x10
-11
  kg  per  pa-sec-m
)  or  less  with 
openings gasketed or sealed and
b.  weather  stripping  has  been  added  on 
openable windows and doors and
c.  caulking or sealants are applied to areas 
such as joints around window and door 
frames, between sole plates and floors, 
between wall-ceiling joints, between wall 
panels,  at  penetrations  for  plumbing, 
electrical and gas lines and at other open-
ings.
If  your  home  meets  all  of  the  three  criteria 
above, you must provide additional fresh air. 
See Ventilation Air From Outdoors, page 7.
If your home does not meet all of the three criteria 
above, proceed to Determining Fresh-Air Flow 
For Heater Location
, page 6.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/
NFPA 54
 defines a confined space as a space 
whose volume is less than 50 cubic feet per 
1,000 Btu per hour (4.8 m
3
 per kw) of the ag-
gregate input rating of all appliances installed 
in that space and an unconfined space as a 
space whose volume is not less than 50 cubic 
feet per 1,000 Btu per hour (4.8 m
3
 per kw) 
of the aggregate input rating of all appliances 
installed in that space. Rooms communicating 
directly with the space in which the appliances 
are installed*, through openings not furnished 
with doors, are considered a part of the un-
confined space.
* Adjoining rooms are communicating only if 
there are doorless passageways or ventilation 
grills between them.