Figure 3 - Ventilation Air from Outdoors
vENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining 
unconfined  space.  When  ventilating  to  an 
adjoining unconfined space, you must provide 
two permanent openings: one within 12" of the 
ceiling and one within 12" of the floor on the 
wall connecting the two spaces (see options 
1 and 2, Figure 2). You can also remove door 
into adjoining room (see option 3, Figure 2). 
Follow  the  National  Fuel  Gas  Code, ANSI 
Z223.1/NFPA  54,  Section  5.3, Air  for  Com-
bustion  and  Ventilation
  for  required  size  of 
ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside 
Building
Or  
Remove  
Door into  
Adjoining  
Room,  
Option 3 
Ventilation Grills  
Into Adjoining Room, 
Option 2 
12" 
12" 
Ventilation
Grills into
Adjoining
Room, 
Option 1
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
AIR FoR CoMBUsTIoN 
ANd VeNTIlATIoN
Continued
INsTAllATIoN
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or 
propane/LP).  If  your  gas  supply  is  not  the 
correct  gas  type,  do  not  install  heater.  Call 
dealer  where  you  bought  heater  for  proper 
type heater.
This  appliance  is  only  for  use 
with the type of gas indicated on 
the rating plate. This appliance 
is  not  convertible  for  use  with 
other gases.
  WARNING:  This  appliance 
is equipped for natural or pro-
pane/LP  gas.  Field  conversion 
is not permitted.
ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open 
to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel 
Gas  Code, ANSI  Z223.1/NFPA  54,  Section 
5.3, Air  for  Combustion  and  Ventilation  
for 
required size of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.