GETTING YOUR HEAT PUMP STARTED & STOPPED 
(Continued) 
 
8.  In operation, whenever the actual (displayed) water temperature falls below 
the desired set point, the unit will start heating after an initial time delay of 
3-4 minutes. 
 
NOTE:  T
HE HEAT PUMP INCORPORATES AN ANTI
-
SHORT CYCLE TIME DELAY
. S
HOULD 
OPERATION BE INTERRUPTED
RESTART WILL BE DELAYED BY APPROXIMATELY 
4-
MINUTES
CONTINUOUS USAGE AND WATER AROUND UNIT 
If you have followed the directions up to this point, you should be on your way to 
enjoying a warm pool or hot spa. 
After the heat pump has been running for some time, you may see water present 
around the heater.  This water is condensation produced as a by-product of 
transferring heat from the air to your pool or spa.  If the humidity is high, water 
quantities of  6-8 gallons per hour are not uncommon.  Conversely, a low-
humidity condition may result in no condensation being produced. 
REQUIRED HOURS OF POOL PUMP OPERATION 
S
OME POOL SYSTEMS UTILIZE A TIMER TO CONTROL THE POOL FILTER PUMP ON A TIME
-
OF
-
DAY 
BASIS
.  I
F YOUR POOL SYSTEM INCORPORATES A TIMER
USE THE FOLLOWING INSTRUCTIONS
 
It will be necessary to allow your pool circulator pump to run continuously until 
the pool has reached the desired temperature.   
If a timer controls your pump, it will be necessary to override the timer to 
temporarily allow for 24-hr. pump operation. 
Once the desired temperature has been obtained (this may take up to four days), 
you should reset your pump time clock for normal operating hours. 
 
R
EMEMBER 
… 
THE HEAT PUMP CAN ONLY OPERATE WHEN THE CIRCULATOR 
P
UMP IS RUNNING
.  T
HEREFORE
IN ORDER TO KEEP UP WITH INCREASED HEAT 
LOSS DURING COOLER WEATHER
,
 IT MAY BE NECESSARY TO EXTEND THE PUMP
DAILY HOURS OF OPERATION
TO SHUT THE UNIT OFF 
The unit can be stopped by switching off the electrical supply or by setting the 
desired temperature lower than the actual water temperature. 
The unit will display “OFF” if the desired water temperature is set below 60°F.