DIGITAL CONTROLLER- OPERATIONAL DISPLAYS 
T
HE FOLLOWING CODES WILL BE DISPLAYED AS PART
 
 OF THE NORMAL OPERATION OF THE HEATER
 
 
OPERATIONAL CODES 
 
FLO—No water flow detected.  Code message will appear any time the 
circulating pump is off, or when the heater is not receiving correct water 
flow. 
OFF—System is off.  System is off until temperature set point is raised 
above 60°F. 
CFI—Celsius / Fahrenheit Selection.   
ULC—User Lock Code.  When activated, steps to the next menu level: 
ELC. 
ELC—Enter Lock Code.  Allows end user to select a secret code so only 
authorized persons can change heater settings. 
CFO—Call Flex Options.  When activated, steps to the next menu level: 
CFS. 
CFS—Call or Flex selection.  Allows user to choose between call or flex 
options.  
FS—Heater in defrost mode.  Normal function in lower air temperatures.  
Fan continues to run and compressor is off.  Compressor will restart when 
air coil temperature rises to approximately 38°F. 
 
 