Heat Controller BG-143G Manual Do Utilizador

Página de 36
 
 
PROBLEM 
POSSIBLE CAUSE 
TO CORRECT 
Defective motor. 
Check and replace. 
Open or shorted capacitor. 
Replace capacitor and check. 
Condenser fan frozen to Chassis.  Check if drain pan valve is open. If not, 
replace. 
Fan motor 
does not 
operate in 
"Constant" 
speed or 
"Auto” speed. 
Loose connections. 
Check all connections. Check voltage to fan 
motor. 
Fuse link. 
Check fuse link for continuity. If defective, 
replace. 
Heating element shorted. 
Check amperage draw of element. If no 
amperage, replace. 
Incorrect wiring. 
Check voltage to element. If voltage is okay, 
check wiring.   
Unit does not 
heat. 
Heat relay or heater contactor coil 
open. 
Defective coil. Test coil for continuity. 
 
 
Service Manual
Room Air Conditioner with R-410A
Heat Controller, Inc.
33