7.  FUNCTIONS
7-1.  Operation Functions
Emergency operation
SENSOR DRY
 During DRY operation, the system adjusts the room 
temperature and fan speed according to the conditions in the 
room, in order to maintain a comfortable room environment.
SENSOR DRY operation
DRY operation is as shown in the figure below.
PAM-    control
  In order to further improve inverter performance, control is 
switched between PWM control at low operation speeds, and 
PAM control at high operation speeds, making the most 
effective use of power.
 The compressor operation frequency varies.
 The indoor fan operates with 1/f fluctuation.
 The compressor operates at a low operating frequency.
 The indoor fan operates with 1/f fluctuation.
  Monitoring operation takes place when the room temperature 
is below 59°F
(
15°C), or more than 5°F
(
3°C) below the set 
temperature.
  When the monitoring range is entered, the compressor stops, 
and the indoor fan operates with 1/f fluctuation.
DRY A
DRY B
Monitor
Conditions are monitored at all 
times when the room temperature 
is below 59°F(15°C).
Load
COOL zone
A zone
B zone
Emergency operation is available when the remote 
controller malfunctions, has been lost, or otherwise 
cannot be used.
  The set temperature is 4°F(2°C) below the detected room 
temperature in the case of cooling operation.
(GREEN) (Lamp 
Off)
COOL
STOP
To operate the system, press the OPERATION button, 
which is also used as the receiver, below the unit display. 
Each time this button is pressed, the OPERATION lamp 
changes color to indicate the type of operation. Select the 
desired type of operation.
The Sensor Dry operation during the Low Ambient Cooling 
Mode (outside air temperature:59°F(15°C) or lower) is as 
follows. 
The compressor operates a cycle of 3 minutes ON and 6 
minutes OFF repeatedly.
NOTE
DRY A
DRY B
and
(CLxx models only)