HIGH POWER
NIGHT SETBACK
Lamp colors
Timer backup
This function acts to raise the power but keeps the AC system in 
the same operating mode.
This function is set with the HIGH POWER button on the remote 
controller.
(It can be set regardless of the temperature and fan speed 
settings.)
 HIGH POWER operation from remote controller
 The unit operates at maximum output for 30 minutes, 
regardless of the desired temperature.
 The fan speed is 1 step above "High."
OPERATION lamp
 When HIGH POWER operation ends, the unit operates at low 
Hz for 5 minutes, regardless of the thermostat OFF conditions.
 When in DRY mode, operation is in the cooling zone.
  Operation stops if there are no operator controls for 25 hours or 
longer after unit operation switched from OFF to ON by use of 
ON timer operation.
Frequency
MAX
0
Start
End
Time
30 min.
5 min.
Setting
temperature
Press the NIGHT
SETBACK button
  When NIGHT SETBACK operation is set, the temperature and 
fan speed settings will be adjusted automatically to allow 
comfortable sleep.
  When NIGHT SETBACK operation is set, "     mark" appears on 
the remote controller. The main unit display lamp also becomes 
dimmer.
COOL and DRY modes
When the night setback mode is selected, the air conditioner 
automatically raises the temperature setting 2°F(1°C) when 30 
minutes have passed after the selection was made, and then 
another 2°F(1°C) after another 30 minutes have passed, 
regardless of the indoor temperature when night setback was 
selected. This enables you to save energy without sacrificing 
comfort. This function is convenient when gentle cooling is 
needed.
TIMER lamp
Green
QUIET lamp
Green
ION lamp
Green
DRY operation
Orange
COOL operation
Green
NOTE
30 min.
30 min.
Time
2
°F(
1
°C)
2
°F(
1
°C)
33