Sanyo XH3672R / C3672R Manual Do Utilizador

Página de 180
1
2
3
4
5
6
IV-8
SM831148
4. Service procedures
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
[Alarm “P29”]
(MDC trouble)
(1)
Input power detection circuit trouble
Compressor does not run.
Breakdown
Motor current detection circuit trouble
Is power OK?
Correct power line.
Is
current
detection
circuit wiring
OK?
Check and correct 
wiring.
Are
wiring and 
connector
connections
OK?
Check and correct
wiring.
 Is 
compressor
 OK?
 Ground 
fault?
Replace
compressor.
 Coil 
resistor
short circuit?
Coil open 
circuit?
Is there 
abnormal refrigerant 
accumulation?
Replace
compressor.
Is
operation of 
electronic
control valve 
OK?
Replace outdoor 
unit control PCB.
 Are 
C1 and TS 
sensors
OK?
  Replace C1 and 
TS sensors.
Replace electronic 
control valve.
Is there overload?
 Remove 
the cause.
4-3. Details of Alarm Messages