Sanyo SAP-K25AP Manual Do Utilizador

Página de 37
34
13.1 What is self diagnosis function?
When the problem detected in the air conditioner, the operation stops and LED indicator lamps 
on the indoor unit will display the error code (Fig. 42). 
Kindly refer Table 6a,b for the meanings of error code and indications for each models. 
Installation Service
13. SELF DIAGNOSIS FUNCTION
Fig. 42
Table 6a 
Error Code 
(Indoor) 
Diagnostics Item 
Diagnostics contents 
Models 
F1 
Indoor room 
temperature sensor. 
F2 
Indoor heat exchanger 
coil sensor. 
  Sensor opens circuit or short circuit. 
  Contact failure at connector. 
  Indoor P.C.B failure. 
C5 
OTP data 
(Jumper Cap). 
  Jumper Cap on P.C.B failure. 
  Indoor P.C.B failure. 
K12AP, 
K18AP, 
K25AP, 
K30AP. 
H6 
Indoor fan motor lock 
current. 
  Indoor fan motor failure. 
If motor running speed is too slow / 
stop for 1 min., in order to prevent 
motor self-protection activated, it will 
stop running and display lock.  
  Contact failure at connector.  
K12AP, 
K18AP, 
K25AP. 
 
E5 
Overload current 
protection. 
  Indoor P.C.B overload current 
protector activated. 
K18AP, 
K25AP. 
F3 
Outdoor temperature 
sensor. 
  Outdoor dummy Sensor (R1) failure. 
  Indoor / outdoor P.C.B failure. 
K30AP 
only 
F4 
Outdoor heat 
exchanger sensor
.
 
  Outdoor dummy Sensor (R 2) failure. 
  Indoor / outdoor P.C.B failure. 
K30AP 
only 
 
Table 6b. –  ONLY for KC30AP. 
Error Code 
(Indoor) 
Diagnostics Item 
LED  
(Outdoor) 
Diagnostics Contents 
E1 
High pressure 
protection. 
Outdoor P.C.B 
LED 1 blinking. 
  High-pressure switch sensor 
activated / failure. 
E5 
Overload current 
protection. 
Outdoor P.C.B 
LED 2 blinking.  
  Outdoor P.C.B overload current 
protector activated. 
E6 
Communication signal 
between indoor & 
outdoor unit 
failure. 
Outdoor P.C.B 
LED 1, 2, 3 
blinking. 
  Indoor / Outdoor P.C.B failure. 
  Wrong wirings connection. 
  Wirings contact failure. 
Communications signal 
between Indoor & 
outdoor unit 
normal.  
Outdoor P.C.B 
LED 4, 5 blink 
alternately.
 
  It shows that the communication 
signal is correctly under this 
condition. 
 
K9AP,
K9AP,