7.  FUNCTIONS
7-1.  Explanation of Functions
The numerical values such as temperature, frequency, time and current in parentheses are an example 
of SAP-CMRV3146EH and the values are different from the other models.
Control/conditions
INITIAL
Breaker is ON.
Power is supplied to the indoor and outdoor unit 
control circuits, however the unit remains stopped.
Positioning of the outdoor unit electric expansion 
valve is performed.
The ON/OFF operation 
button on the remote 
controller is pressed.
If automatic operation mode has been selected 
with the remote controller, operation begins in 
HEAT, SENSOR DRY, or COOL mode 
depending on the room temperature and 
outdoor temperature at the time operation starts.
Depending on the operational mode, refer to the HEAT, SENSOR DRY, or COOL item.
This applies in the case of automatic 
HEAT/COOL operation.
HEAT
Unit operation
Explanation
The ON/OFF operation 
button on the remote 
controller is pressed.
The unit is forced to stop for 3 minutes after 
the power is turned ON, or 3 minutes after the 
compressor stops, in order to protect the 
compressor.
The frequency is increased at the rate of 1 Hz 
every 0.5 seconds.
Operation lamp illuminates.
Indoor fan is stopped to prevent cold air from 
being emitted.
Outdoor unit begins operating after 
forced-stop is canceled.
This is in order to stabilize the return of oil to the 
compressor.
When the frequency reaches    Hz,frequency 
increases are stopped for a period of    seconds. 
(Refor to Table 2 "Freguency control".)
If the indoor and outdoor temperatures are high, 
the current peak cut-off activates, stopping any 
increases in frequency.
The frequency then increases.
The thermostat turns 
OFF.
The outdoor unit stops. (It does not stop if the 
thermostat for another indoor unit is ON.)
Approximately 30 seconds after the 
thermostat turns OFF, the indoor fan is 
stopped.
The indoor fan is stopped.
The indoor and outdoor 
temperatures are high.
The outdoor unit starts automatically after 3 
minutes.
During these 3 minutes, a low-pressure 
pressure balance is achieved, allowing the 
compressor to start more easily.
In order to protect the compressor, the outdoor 
unit will not operate for 3 minutes after the 
thermostat turns OFF, even if the room 
temperature drops below the desired 
temperature.
The room temperature 
has reached the desired 
temperature.
Operating frequency is stabilized in order to 
maintain a comfortable environment.
The indoor temperature and the remote 
controller temperature setting are 
approximately equal.
The thermostat turns ON.
The unit operated before, and the temperature of 
the indoor heat exchanger is relatively warm.
Therefore,the fan speed may start at the set fan 
speed at the same time that the thermostat turns 
ON.
The indoor unit is stopped.
Depending on the relationship between the 
remote controller temperature setting and the 
room temperature, the compressor may stop 
temporarily (in other words, the thermostat 
may turn OFF).
When the indoor coil temperature rises,
the compressor starts,
the outdoor fan starts,
and the indoor fan changes from "LL" 
to the set fan speed.
The amount of heat pump exceeds the amount 
of heat radiation from the room.
Therefore, there is no need to further increase 
the compressor capacity, and the frequency is 
stabilized or lowered.
The frequency is not increased, even if 
there is a difference between the room 
temperature and the desired temperature.
In some cases, the frequency may be 
decreased.
NOTE