MECHANICAL COMPONENTS
Plenum assembly  Diffuser with directional louvers used 
to direct the conditioned airfl ow.
Blower wheel  Attaches to the indoor side of the fan motor 
shaft and is used for distributing unconditioned, room side 
air though the heat exchanger and delivering conditioned 
air into the room.
Slinger fan blade  Attaches to the outdoor side of the fan 
motor  shaft  and  is  used  to  move  outside  air  through  the 
condenser coil, while slinging condensate water out of the 
base  pan  and  onto  the  condenser  coil,  thus  lowering  the 
temperature and pressures within the coil.
ELECTRICAL COMPONENTS
Thermostat    Used  to  maintain  the  specifi ed  room  side 
comfort level
System switch  Used to regulate the operation of the fan 
motor, the compressor or to turn the unit off. For troubleshoot-
ing, refer to the wiring diagrams and schematics in the back 
of this service manual.
Capacitor  Reduces line current and steadies the voltage 
supply, while greatly improving the torque characteristics of 
the fan motor and compressor motor.
MoneySaver
®
 switch  When engaged, it sends the power 
supply to the fan motor through the thermostat, which allows 
Smart Fan  Automatically adjusts the fan speed to main-
tain the desired room temp. 
for a cycle-fan operation.
Fan  Motor    Dual-shafted  fan  motor  operates  the  indoor 
blower wheel and the condenser fan blade simultaneously.
Heating element  Electric resistance heater, available in
EQ08 model.
Heat anticipator  Used to provide better thermostat and 
room air temperature control.
HERMETIC COMPONENTS
Compressor  Motorized device used to compress refrigerant 
through the sealed system.
Capillary tube  A cylindrical meter device used to evenly dis-
tribute the fl ow of refrigerant to the heat exchangers (coils.)
FUNCTIONAL COMPONENT DEFINITIONS
12