Enviro 1200 Freestanding Manual Do Utilizador

Página de 45
Installation
M
ASONRY
 F
IREPLACE
 I
NSTALLATION
 - I
NSERT
:
Unless you are experienced, we recommend installation by your dealer or a 
professional installer.
It  is  recommended  that  you  install  the 
decorative  plates  (if  purchased)  into  the 
shrouds  before  installing  the  unit.  Refer  to 
“I
NSTALLATION
  O
F
  P
ODS
 
AND
  D
ECORATIVE
  P
LATES
  - 
I
NSERT
”.
Install only in a masonry fireplace at least 25” (635 
mm)  wide,  22”  (560  mm)  high  and  14”  (356  mm) 
deep  with  a  good-condition  chimney  at  least  15  ft 
(4.6 m) high, both of which have been constructed 
in  accordance  with  the  building  code.  Be  sure  the 
fireplace  and  chimney  are  clean  and  sound  without 
any cracks or loose mortar. Do not remove any bricks 
or mortar from the fireplace.
If there is a combustible floor in front of the masonry 
fireplace,  the  fireplace  insert  must  be  8”  (203  mm) 
above the combustible floor, and floor protection must 
be  provided  18”  (457  mm)  in  front  of  the  fireplace 
insert and 8” (203 mm) to each side of the unit.
1.  Remove  any  fireplace  damper  or  fasten  in  a 
permanent open position.
2.  (IN  CANADA)  The  stove  is  vented  with  a  6” 
stainless  steel  liner  that  goes  directly  to  the  top  of 
the  chimney  and  is  covered  with  a  rain  cap.  The 
chimney  top  is  sealed  with  a  flashing  or  steel  plate 
that  supports  the  weight  of  the  chimney  liner.  The 
installation must conform to the liner’s manufacturer’s 
instructions.
This fireplace must be installed with a continuous 
liner  of  6”  diameter  (CANADA  ONLY)  extending 
from  the  fireplace  insert  to  the  top  of  the 
chimney. The chimney liner must conform to the 
class  3  requirements  of  ULC-S635  Standard  for 
Lining  Systems  for  Existing  Masonry  or  Factory-
Built Chimneys and Vents, or ULC-S640 Standard 
for Lining Systems for New Masonry Chimneys.
(IN  U.S.A.)The  appliance  when  installed,  must 
follow  local  building  codes,  in  the  absence  of 
local building codes, with the current NFPA 211 
Standard  for  Chimneys,  Fireplaces,  Vents,  and 
Solid Fuel-Burning Appliances.
Floor
Protection
Combustible Floor
Masonry Fireplace
18"
(457 mm)
8"
(203 mm)
Rain Cap
Steel Plate or Flashing
Flexible or Rigid 6"
Stainless Steel Liner
Mantel
Top Facing
Damper Removed
or Fastened Open
Sheet Metal Screws
Fastening Collar to
Stainless Steel Liner
Face Plate
Floor Protection
Combustible Floor
Masonry Fireplace
18"
(457 mm)
8"
(203 mm)
Figure 29: Insert Installation into existing fireplace 
with hearth.
Figure 30: Insert Installation into existing fireplace 
without hearth.
28