Lightolier Baselyte-BSL19 Manual Do Utilizador

Página de 5
Lighting Systems
 
Baselyte-BSL19
Page 2 of 5   
2 Light T8 Wall Mount Semi-Indirect
Lightolier 
a Genlyte Company 
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information 
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
Report No: 9900043
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 69.8%
Up: 95.6%  Down: 4.4%
Zonal Lumen Summary
ZONE        LUMENS        %BARE LAMP       %LUMINAIRE
CANDLEPOWER SUMMARY
ZONE
CANDLEPOWER
DEG.
0
45
90
135
180
180
889
889
889
889
889
175
928
915
884
880
879
165
1023
965
856
851
854
155
1113
1004
798
800
807
145
1188
1017
719
728
758
135
1245
1002
613
651
714
125
1314
993
488
577
688
115
1196
974
343
522
636
105
761
700
194
413
457
95
276
231
47
115
110
90
38
20
2
4
3
85
42
23
4
4
3
75
56
35
8
4
3
65
68
47
11
5
4
55
77
57
19
8
6
45
82
63
27
11
8
35
82
66
36
19
14
25
77
66
43
29
24
15
68
61
48
39
35
5
57
55
51
47
46
0
51
51
51
51
51
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
67
67
67
58
58
58
40
40
40
1
58
56
53
50
48
46
35
34
32
2
51
47
43
44
40
38
30
28
27
3
44
40
36
38
34
31
27
24
22
4
39
34
30
34
29
26
23
21
19
5
34
29
25
30
25
22
21
18
16
6
31
25
22
26
22
19
18
16
13
7
27
22
19
24
19
16
17
14
12
8
25
20
16
21
17
14
15
12
10
9
22
17
14
19
15
12
13
11
9
10 20
15
12
17
13
11
12
10
8
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4138
3955.5
182.5
4.4
95.6
100.0
3.1
67.0
70.1
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
67
67
67
58
58
58
40
40
40
1
58
56
53
50
48
46
35
34
32
2
51
47
43
44
40
38
30
28
27
3
44
40
36
38
34
31
27
24
22
4
39
34
30
34
29
26
23
21
19
5
34
29
25
30
25
22
21
18
16
6
31
25
22
26
22
19
18
16
13
7
27
22
19
24
19
16
17
14
12
8
25
20
16
21
17
14
15
12
10
9
22
17
14
19
15
12
13
11
9
10 20
15
12
17
13
11
12
10
8
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4138
3955.5
182.5
4.4
95.6
100.0
3.1
67.0
70.1
Module Lengths & Mounting Distances
Run Configuration 
Run
Length 
4’ 
Module
8’
Module
2’ 
Module
Joiner
End Set
Mount
Power 
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
3
-ODULE
-OUNTING
-ODULE
-ODULE
@
@
@
Note: Shaded area indicates locations of emergency sections (emergency wiring  
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO 
lamping options, longer runs, and runs with wiring options that are more complex. 
Please consult factory for assistance.
Joiner
BSLEWW = wall mount standard white
Dust Cover
End Set
BSLJW = wall mount joiner 
BSLDCW = 4’ wall mount dust cover 
System Components & Accessories
Non-Power Wall Mount
Power Wall Mount
BSLWP1 = -power mount
BSLWP2 = 2-power mount
BSLWN = non-power wall mount