Lightolier Baselyte-BSL19 Manual Do Utilizador
Lighting Systems
Baselyte-BSL19
Page 3 of 5
2 Light T8 Wall Mount Semi-Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Wiring Options: 1 Circuit
1 Circuit with Emergency Circuit/Night Light (EC/NL)
One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal
circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.
circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.
Type 3: cct. w/EC/NL
All lamps wired on one circuit.
1 Circuit
Type 5: Chloride standard
C700A
Type M: Bodine standard
B70A
Type E: Chloride high performance
C400
Type P: Bodine high performance
B50
C700A
Type M: Bodine standard
B70A
Type E: Chloride high performance
C400
Type P: Bodine high performance
B50
All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected
to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by
installer. Leads for both normal circuit and battery pack are wired to fixture ends.
to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by
installer. Leads for both normal circuit and battery pack are wired to fixture ends.
1 Circuit with Emergency Battery Pack (EM)
One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery
pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together
or wire separately if controlled independently. Leads for normal circuit, EC/NL and EM wired to
fixture ends. All lamps in EC/NL section to be wired together.
pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together
or wire separately if controlled independently. Leads for normal circuit, EC/NL and EM wired to
fixture ends. All lamps in EC/NL section to be wired together.
1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack
Type J: Chloride standard
C700A
C700A
%#.,
%#.,
�
�
�
�
�
%-
%#.,
%#.,%-
Type 1: cct.
Type 8: cct. w/cct. thru wire
Type H: cct. w/2cct. thru wire
Type 7: cct. w/dimming
Type 8: cct. w/cct. thru wire
Type H: cct. w/2cct. thru wire
Type 7: cct. w/dimming
*Note: Multi-lamp battery packs are also available.
*Note: Multi-lamp battery packs are also available.