Lightolier ADS8G16MS140 Folheto

Página de 2
VP PARABOLIC
ADS8G16MS140
Page 1 of 2
8”x48” RECESSED FLUORESCENT16 CELL PARABOLIC LOUVER 
STATIC IES RP24 PREFERRED
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
PERFORMANCE 
In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1
reflectance 80% ceiling, 50% post-wall, 20% floor the CU. shall no be less than
0.69. To prevent glare the VCP shall not be less than 88 either lengthwise or
crosswise (at 100 fc level) and that the average luminance will conform with the
IES RP-24 preferred standard, and have a fixture efficiency of not less than 60%.
MATERIALS
Chassis parts are die-formed 20 gauge cold rolled steel.
LOUVER
Post-anodized aluminum.
FINISH
Louver - Low iridescense specular post-wall, anodized vertical grain sheet or
Low iridescence reflector matte post-anodized vertical grain sheet. Chassis exte-
rior white baked polyester powder coat.
ELECTRICAL
Rapid start HPF thermally protected class “P” ballast CBM certified by ETL if
K.O. is within 3” of ballast use wire suitable for at least 90”.
LABELS
Listed by CSA/UL.
• Meets IES RP-24 Preferred Practice.
• Ideal for intensive VDT use areas.
• Only 5.5” deep.
• Utilizes CFI Advance Technology Reflector Louver.
• Precise fitting reflector louver.
• Louver securely held with CFI concealed torsionite spring clips
• Fixture Efficiency 62.4%
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 2/Folio G09-10