Canon GC-251 Manual Do Utilizador
CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
36
4.2. Step
Movement
Execute step movement for a fixed angle.
GALILEO
・Select the Step Move tab. ①
・Select an axis for step movement. ②
・Specify the displacement (angle and pulse count) for relative position (STEP) and absolute
position. ③
・Press the MOVE button (either positive or negative position direction can be specified). ③
RS-232C command
・
Target value setting mode (Command ID = 10)
・
Target position setting (Command ID = 20)
・
Movement start (Command ID = 8)
①
②
③