4.4. 
Position Command Input by High-speed Serial Communication 
For a vector scan, give target position data to the controller by high-speed serial communication, The 
data is updated as required. 
Switch the controller to the status of receiving target position data by high-speed serial communication. 
For switching, it is necessary to enter high-speed serial communication signals into the controller in 
advance. 
GALILEO 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Select an axis for high-speed serial communication. ① 
Switch HiSpeed Serial to Start. ② 
This switching makes the controller follow target position data by high-speed serial communication. 
Switch HiSpeed Serial to OFF. ② 
  Input of the MOVE command is awaited. 
 
RS-232C commands 
・ 
Switch to high-speed serial communication (Command ID = 23 Data = 7) 
・ 
Return to internal clock operation (Command ID = 23 Data = 0)